Menu
The basic SI unit of force is the newton, which has the symbol N.One newton is defined as the force necessary to give a mass of 1 kg an acceleration of 1 m/s2. The acceleration due to gravity is normally taken as 9.81 m/s2. This is the acceleration imparted to a 1 kg force by its own weight (1 kg-force). Hence:
1 kg-force = 9.81 N
1 tonne-force = 9810 N or 9.81 kN
1 tonne-force = 9810 N or 9.81 kN
Note: For less precise calculations the value of g is often taken as 10 m/s2. The SI unit of pressure and stress is the pascal, which has the symbol Pa.
Results and Analysis of ejectors using our software: Discussion and guidelines, what to look for, design curve versus operating curve. The entrainment ratio can then be varied, to generate ejector curves like the one below. (PR is the ratio of motive gas to entrained gas pressure). Note that these curves are for specific temperatures and gas. Design features and operation of jet ejectors. Relative suction flow of steam jet vacuum ejectors. The result of calculation will be identical with the. Download full-text PDF. Review of ejector design parameters and geometry for refrigeration. Air conditioning. This procedure introduces a. Calculation for the ejector design using the correlations is also developed. Viscosities of up to 500 Cp. Can be utilized with just small modifications. For higher viscosities (programs above 500 Cp.), we suggest that you function with your qualified representative or the programs workers at.
1 Pa = 1N/m2
1MPa= 1 MN/m2 or 1 N/mm2
1 GPa = 1 GN/m2 or 1 kN/mm2
1MPa= 1 MN/m2 or 1 N/mm2
1 GPa = 1 GN/m2 or 1 kN/mm2
Note: The SI system actually uses the designation 9/81 ms–2 for the acceleration of gravity (g) and a similar system for other units. However, to avoid confusion the traditional
designation is being used here.
designation is being used here.
Formulae
The following formula may be used for calculating the ejection force:
The following formula may be used for calculating the ejection force:
This is the way the formula is usually written in scientific texts but a slightly easier form for computational purpose is:
where:
Fp = the ejection resistance force (N)
E = Young’s modulus of the polymer (N/cm2)*
A = total surface area of moulding in contact with cavity or core, in line of draw (cm2)*
Fp = the ejection resistance force (N)
E = Young’s modulus of the polymer (N/cm2)*
A = total surface area of moulding in contact with cavity or core, in line of draw (cm2)*
μ= coefficient of friction, polymer on steel
m = Poisson’s ratio
d = the diameter of a circle whose circumference is equal to the total projected perimeter of the moulding (cm)*
∝= the coefficient of linear expansion of the polymer (cm/°C)*
Δt= (polymer softening temperature) ? (mould tool temperature) (°C)
t = average wall thickness of part (cm)*
*Note that the units of length here are all in cm.
d = the diameter of a circle whose circumference is equal to the total projected perimeter of the moulding (cm)*
∝= the coefficient of linear expansion of the polymer (cm/°C)*
Δt= (polymer softening temperature) ? (mould tool temperature) (°C)
t = average wall thickness of part (cm)*
*Note that the units of length here are all in cm.
Example
A two-impression thin walled box-shaped component is to be moulded on a 275 tonne press. The machine has an ejector force rated at 40 kN. Calculate whether this is sufficient given the following data:
A two-impression thin walled box-shaped component is to be moulded on a 275 tonne press. The machine has an ejector force rated at 40 kN. Calculate whether this is sufficient given the following data:
Ejector Design Calculation Software Online
Material: Polystyrene (PS)
Young’s modulus of elasticity: 300,000 N/cm2
Poisson’s ratio: 0.35
Coefficient of friction (PS on steel): 0.4
Softening temperature of PS: 80 °C
Mould tool temperature: 20 °C
Coefficient of linear expansion (PS): 0.00007 cm/°C
The dimensions of the box are shown in Figure 10.8: all dimensions are in cm.
Young’s modulus of elasticity: 300,000 N/cm2
Poisson’s ratio: 0.35
Coefficient of friction (PS on steel): 0.4
Softening temperature of PS: 80 °C
Mould tool temperature: 20 °C
Coefficient of linear expansion (PS): 0.00007 cm/°C
The dimensions of the box are shown in Figure 10.8: all dimensions are in cm.
Total area of resistance = 2 x (12 x 15) + 2 x (12 x 25) = 360 + 600 = 960 cm2
Total projected perimeter = 2 x 15 + 2 x 25 = 80 cm
Hence:
d = 80/π = 25.46 cm and Δt = 80 ? 20 = 60 °C
Therefore,
Total projected perimeter = 2 x 15 + 2 x 25 = 80 cm
Hence:
d = 80/π = 25.46 cm and Δt = 80 ? 20 = 60 °C
Therefore,
p F = 13 824 N, or 13.8 kN
Hence for a two-impression tool we require 2 x 13.8 kN = 27.6 kN. This is well within the machine specification of 40 kN; however, in practice the machine ejection force will also be subject to the sliding resistance of the ejector system and sometimes to force
exerted by any return springs used in the ejector assembly.
exerted by any return springs used in the ejector assembly.
A good rule of thumb is to apply a factor of 1.25 for nonspring systems and 1.5 for spring return systems. Therefore, in this case the total ejection resistance force is:
1.25 X 27.6 = 34.5 kN for non-spring systems, or
1.5 X 27.6 = 41.4 kN for spring return systems
This demonstrates that the machine ejection force is satisfactory for the first case but unsatisfactory for the second case.
1.5 X 27.6 = 41.4 kN for spring return systems
This demonstrates that the machine ejection force is satisfactory for the first case but unsatisfactory for the second case.
Please contact me if you would like a excel spread sheet for this calculation.
The Pipe Flow Expert software will allow you to easily draw and model a piping design. The pipe system is defined using Pipe Flow Expert's incredibly intuitive user interface, which also supports isometric 3D piping layouts.
Piping Design and Pipeline Modeling
The piping model will typically include standard physical data such as:
- The internal size, internal roughness and length of each pipe.
- The elevation of each node (join point) where several pipes connect.
- The additional in-flow or out-flow (take off) at any particular node.
- The elevation, liquid level and surface pressure data for each tank.
- The flow versus head performance data for each pump.
Autocad 2000 full crack. The calculated results include the flow rates for each pipe, the fluid velocities for each pipe, Reynolds numbers, friction factors, friction pressure losses for each pipe, fittings losses, component pressures losses, node pressures, pipeline HGL (Hydraulic Grade Line), pump operating points (including pump head required) and more.
Flow Rate and Pressure Drop Calculations
Pipe Flow Expert calculates the balanced steady state flow rates, pipe pressure drops and node pressures within a piping system.
The Colebrook-White friction factor equation is used to determine the correct pipe friction factors and the Darcy-Weisbach friction loss calculation method is used to calculate the pipe friction losses.
Solving the Piping Design
To solve and calculate the flow and pressure loss results the following conditions have to be satisfied:
- Conservation of Mass Flow must be maintained, i.e. there must be mass flow continuity at every node (point where multiple pipes join) within the pipe system.
- Conservation of Energy must be maintained, i.e. the algebraic sum of the pressure losses around a loop in the pipe network must be zero.
Ejector Calculation
The second condition can also be related to 'pseudo-loops' (any path between two tanks or end points in the system) such that the algebraic sum of the pressure losses in the pipes along the path must equal the difference in pressure between the start and end point.
Method of Solution
Pipe Flow Expert generates the fundamental conservation of energy and conservation of mass flow equations from the piping system model. It then uses advanced mathematical matrix methods to solve the resulting hydraulic equations, taking account of pumps, components, flow controls, PRVs, BPVs, pipe fittings, pipe materials, pipe sizes, and fluid data.
The final solution is then checked by a second algorithm which compares the calculated pressure at all adjacent nodes to ensure that the pressure difference is equal to the pressure loss resulting from the flow in the pipe joining the nodes. This double check of the pipe network verifies that the calculated pressure at each node is consistent, irrespective of which path through the network is used to calculate the pressure loss back to a particular pressure reference.
![Design Design](https://static.wixstatic.com/media/0d4b96_9a627cbef48f4e80b135fdf5a7447dd0~mv2.png/v1/fill/w_782,h_306,al_c,usm_0.66_1.00_0.01/0d4b96_9a627cbef48f4e80b135fdf5a7447dd0~mv2.png)
Finding an accurate solution of the flows and pressures in a pipe network is not an easy task. It is many orders of magnitude more difficult than finding the pressure loss in a single pipe for a known flow rate, which is why it is important to use proven software with a reliable calculation engine. Pipe Flow Expert is trusted by users in over 100 countries worldwide.